FacebookTwitterDiggStumbleuponGoogle BookmarksRedditTechnoratiLinkedin

Welcome

The Martin Fleischmann Memorial Project is a group dedicated to researching Low Energy Nuclear Reactions (often referred to as LENR) while sharing all procedures, data, and results openly online. We rely on comments from online contributors to aid us in developing our experiments and contemplating the results. We invite everyone to participate in our discussions, which take place in the comments of our experiment posts. These links can be seen along the right-hand side of this page. Please browse around and give us your feedback. We look forward to seeing you around Quantum Heat.

Join us and become part of the project. Become one of the active commenters, who question our work and suggest next steps.

Or, if you are an experimenter, talk to us about becoming an affiliated lab and doing your work in a Live Open Science manner.

I found, yesterday, a very reasonable explanation for why the cells showed a large difference.  It's all about the difference in ambient that each cell sees.  The write up is in our EverNote experiment notebook here:  https://www.evernote.com/pub/malachiheder/celanicellusv1.3evernotelog

That meant that I had to make an addendum to my preliminary report I made a couple weeks ago.  That is here:  Report with Addendum

Dr Kidwell, my happiness is off the charts.

The end result is that I am even more committed to surveying the history of experiments and replications and look for opportunities to do validation/replication. 

 

 

Add comment


Security code
Refresh

Comments   

 
0 #10 Birgit 2024-07-17 13:42
I'm really enjoying the design and layout of your website.

It's a very easy on the eye which makes it much
more pleasant for mee to come here and visit
more often. Didd you hire out a developer to create your theme?
Exceptional work!

My web blog Residential
locksmith: mobilelocksmithwallsend.Co.uk/
Quote
 
 
0 #9 Lee 2024-05-20 22:47
Hi! Someonbe in my Facebook group shared this website with us so I came
to give it a look. I'm definitely loving the information. I'm
bookmarking and will bbe tweeting this to my followers!
Great blog and fantastic style and design.

Feel free to visit my web page: mobile locksmith wallsend: images.google.com.my
Quote
 
 
0 #8 Leif 2023-12-14 04:37
Thanks vpn for android tv iptv (google.ki: www.google.ki/) your
marvelous posting! I actually enjoyed reading it, you are a great
author.I will remember to bookmark your blog and will come back later on. I want to encourage
you continue your great work, have a nice afternoon!
Quote
 
 
0 #7 Kennith 2023-11-20 09:24
I really like what you guys tend to be up too.

This kind of clever work and reporting! Keep up the
awesome works guys I've added you guys to my own blogroll.


My bloog post discuss: Bookmarkstore.download/.../
Quote
 
 
0 #6 charlie tapp 2013-09-25 15:46
@ryan hunt so in laymans terms so i can understand would the 6% be 1.06 cop. and can we even say with out a doubt that it at least breaks even ? what is cop on the average for all tests ( .90 .95 .98 ) ? would breaking even be 1.00 ?
Quote
 
 
0 #5 Ryan Hunt 2013-09-24 20:08
There are currently no tests that are beyond doubt. We have seen in some of the tests about 6%. We have definitely not seen anything like the 40% from Celani's original demo.
Quote
 
 
0 #4 charlie tapp 2013-09-24 19:02
@Ryan hunt what to date have we shown for a cop on any of the cells for sure ? With no doubts
Quote
 
 
0 #3 Ryan Hunt 2013-09-20 14:45
Ed, lovely graphs and discussion, as usual. Your two graphs tell me that the T_Ext1 is modulated by the general trend in Ambient AND the Difference between the two cells as well. Someone more clever at math can probably derive T_ext=F((T_amb_ average),(T_amb difference)) for a given power.
It also looks like our measure of Ambient, in addition to being affected by the cell temperature slightly, is either not a good representation of the ambient experienced by the cells, or there are higher order effects of the ambient on the measured temperature.
Quote
 
 
0 #2 Robert Greenyer 2013-09-20 08:31
@Edwin Pell

The ambient sensors are in line of site for the wire (through the borosilicate) in the US set-up and despite being shielded have demonstrated that they are effected. In one shutdown from say 120ºC glass temp to room temp, I recall the ambient sensor dropped 0.8ºC, I haven't gone back to the data to confirm, but if ambient was 22ºC - this would represent a 3.6% change in 'ambient reading'. One thing to note, that if there was some IR from the wire that was not thermalised/emi tted due to the Borosilicate tube, then this might possibly be thermalised on the ambient sensors opaque shielding.

Although there is only 1 ambient sensor in the EU cells, it is not in line of sight of the wires it is between the much cooler end flanges so there is no chance of wire IR influence and effects from the higher glass temp. It is also in a white polystyrene sphere to diffuse bounce incident thermal radiation and would receive 50% incident from 1 each of both cells end flanges. In addition it is also at the same vertical elevation in the room as the cells centre so is exposed to the same vertical thermocline. This came about through testing of the room in France and noticing that different elevations read different temps, which is to be expected. Lastly, the thermostat for the room HVAC is in the same plane between the linearly arranged cell end flanges.
Quote
 
 
0 #1 Edwin Pell 2013-09-19 20:17
Malachi, here is a plot of (cell B Trise - cell A Trise) and TambA-23 and TambB-23. My understanding is that Trise B is TextB - TambB, likewise for A.

1abcdefghijklmnopqrstuvwxyz2abcdefghijklmnopqrstuvwxyz

I do not see how the ambient can effect the delta of the two cells. Any delta A vs B in the ambient is already removed. The plot is (cell B Text - cell B amb) - (cell A Text - cell A amb)

There are various peaks and valleys at positions 1s, 1x, 2, 2b, 2j, 2k-m that are not matched between the two ambient and delta. And the big negtaive in delta is not matched by any thing happening in the ambient.

Where is the Tamb sensor placed? Is it seeing the IR radiation from the wire?

Here is delta Text and delta Tamb it seems 8% of the delta Text is measured in delta Tamb. I think the causal arrow is delta Text is influencing delta Tamb. Also note the correlation is not very good, some times the two are completely out of sync.

Quote
 

Here is your generous contributions so far towards our $500,000 target, thanks everyone! : $45,020   Please Donate