The Martin Fleischmann Memorial Project is a group dedicated to researching Low Energy Nuclear Reactions (often referred to as LENR) while sharing all procedures, data, and results openly online. We rely on comments from online contributors to aid us in developing our experiments and contemplating the results. We invite everyone to participate in our discussions, which take place in the comments of our experiment posts. These links can be seen along the right-hand side of this page. Please browse around and give us your feedback. We look forward to seeing you around Quantum Heat.

Join us and become part of the project. Become one of the active commenters, who question our work and suggest next steps.

Or, if you are an experimenter, talk to us about becoming an affiliated lab and doing your work in a Live Open Science manner.

We found out that the new curve parameters for the calibration based on T_GlassOut fits way better if we use the correct X and Y columns.  Yell

T_Rise is now based on T_GlassOut minus T_ambient.

We plugged in the new calibration formula based on the graph below to calculate P_out as a function of T_rise.

 

And P_xs (the excess energy calculation is P_out minus P_in.

 

 

 

 

Add comment


Security code
Refresh

Comments   

 
0 #3 XAngus 2018-08-22 17:46
Hi admin. It was hard to find this site in google. It's
not even in top10. You should focus on high quality backlinks from top websites in your niche.

I know of a very effective free method to get high quality links
and instant traffic. The best thing about this method is that you start getting clicks
right away. For more info search in google for: masitsu's tricks
Quote
 
 
0 #2 123star 2012-11-13 08:39
Thank you for providing fit data on the graph! :D

Al Potenza, they already said that they would do that (flux meter with opposite placed sensors) at the end of this post:

quantumheat.org/.../...

But, alas, as you said that would still be "one spot" , I think that your omega flux sensor would be better, because it can be moved easily along the casing to measure the flux at many spots.
Quote
 
 
0 #1 Al Potenza 2012-11-12 22:26
So you're now measuring the temperature of the glass envelope?

Here's a thought. Why not measure the temperature inside AND outside the glass at the same spot? The delta T "across" the glass will be directly proportional to heat flow through the glass. You will have made, in effect, a small, single spot heat flux meter. You can calculate the heat flow from the thermal properties of the glass, its thickness and the delta T but it's more accurate to calibrate that small "heat flow meter" with your heater wire and a known power input.

If you do this in several spots, you can also determine the distribution of heat flow out of the cell through the glass envelope and you can get a rough idea about its uniformity. And yes, I know you can also estimate that with IR measurements.

Just a thought..